New article available
Özsayın Soğutma since 1982

Water Cooled Chiller

Water cooled chiller solutions that operate at a low condensing temperature through a cooling tower — the most efficient choice at high capacities.

257 products · Air- and water-cooled industrial chiller systems

Products · 22 results

You can share your search results as a link.

OzSayin OZ 1201 — Su SoğutmalıNewIn Stock
OzSayin|Su Soğutmalı

OzSayın | OZ 1201

203.3 kWR134aVidalı3~ / 380–400 V / 50 Hz
Adana
Request PricingView
OzSayin OZ 1231 — Su SoğutmalıNewIn Stock
OzSayin|Su Soğutmalı

OzSayın | OZ 1231

230.2 kWR134aVidalı3~ / 380–400 V / 50 Hz
Adana
Request PricingView
OzSayin OZ 1281 — Su SoğutmalıNewIn Stock
OzSayin|Su Soğutmalı

OzSayın | OZ 1281

282.1 kWR134aVidalı3~ / 380–400 V / 50 Hz
Adana
Request PricingView
OzSayin OZ 1311 — Su SoğutmalıNewIn Stock
OzSayin|Su Soğutmalı

OzSayın | OZ 1311

308 kWR134aVidalı3~ / 380–400 V / 50 Hz
Adana
Request PricingView
OzSayin OZ 1351 — Su SoğutmalıNewIn Stock
OzSayin|Su Soğutmalı

OzSayın | OZ 1351

352.8 kWR134aVidalı3~ / 380–400 V / 50 Hz
Adana
Request PricingView
OzSayin OZ 1421 — Su SoğutmalıNewIn Stock
OzSayin|Su Soğutmalı

OzSayın | OZ 1421

416.4 kWR134aVidalı3~ / 380–400 V / 50 Hz
Adana
Request PricingView
OzSayin OZ 1481 — Su SoğutmalıNewIn Stock
OzSayin|Su Soğutmalı

OzSayın | OZ 1481

478 kWR134aVidalı3~ / 380–400 V / 50 Hz
Adana
Request PricingView
OzSayin OZ 1531 — Su SoğutmalıNewIn Stock
OzSayin|Su Soğutmalı

OzSayın | OZ 1531

533 kWR134aVidalı3~ / 380–400 V / 50 Hz
Adana
Request PricingView
OzSayin OZ 1611 — Su SoğutmalıNewIn Stock
OzSayin|Su Soğutmalı

OzSayın | OZ 1611

605.9 kWR134aVidalı3~ / 380–400 V / 50 Hz
Adana
Request PricingView
OzSayin OZ 2411 — Su SoğutmalıNewIn Stock
OzSayin|Su Soğutmalı

OzSayın | OZ 2411

405.5 kWR134aVidalı3~ / 380–400 V / 50 Hz
Adana
Request PricingView
OzSayin OZ 2431 — Su SoğutmalıNewIn Stock
OzSayin|Su Soğutmalı

OzSayın | OZ 2431

433.6 kWR134aVidalı3~ / 380–400 V / 50 Hz
Adana
Request PricingView
OzSayin OZ 2461 — Su SoğutmalıNewIn Stock
OzSayin|Su Soğutmalı

OzSayın | OZ 2461

460.4 kWR134aVidalı3~ / 380–400 V / 50 Hz
Adana
Request PricingView
OzSayin OZ 2511 — Su SoğutmalıNewIn Stock
OzSayin|Su Soğutmalı

OzSayın | OZ 2511

512.7 kWR134aVidalı3~ / 380–400 V / 50 Hz
Adana
Request PricingView
OzSayin OZ 2561 — Su SoğutmalıNewIn Stock
OzSayin|Su Soğutmalı

OzSayın | OZ 2561

563.3 kWR134aVidalı3~ / 380–400 V / 50 Hz
Adana
Request PricingView
OzSayin OZ 2601 — Su SoğutmalıNewIn Stock
OzSayin|Su Soğutmalı

OzSayın | OZ 2601

596.9 kWR134aVidalı3~ / 380–400 V / 50 Hz
Adana
Request PricingView
OzSayin OZ 2631 — Su SoğutmalıNewIn Stock
OzSayin|Su Soğutmalı

OzSayın | OZ 2631

626.6 kWR134aVidalı3~ / 380–400 V / 50 Hz
Adana
Request PricingView
OzSayin OZ 2681 — Su SoğutmalıNewIn Stock
OzSayin|Su Soğutmalı

OzSayın | OZ 2681

674.8 kWR134aVidalı3~ / 380–400 V / 50 Hz
Adana
Request PricingView
OzSayin OZ 2711 — Su SoğutmalıNewIn Stock
OzSayin|Su Soğutmalı

OzSayın | OZ 2711

712.5 kWR134aVidalı3~ / 380–400 V / 50 Hz
Adana
Request PricingView
McQuay WHS2.266.2 — Su SoğutmalıRemanufacturedIn Stock
McQuay|Su Soğutmalı

McQuay WHS2.266.2

730 kWR134aVidalı3~ / 380–400 V / 50 Hz
Adana
Request PricingView
Carrier 30HXC285 — Su SoğutmalıRemanufacturedIn Stock
Carrier|Su Soğutmalı

Carrier 30HXC285

1000 kWR134aVidalı3~ / 380–400 V / 50 Hz
Adana
Request PricingView
Re-OzSayin W-600 — Su SoğutmalıRemanufacturedIn Stock
Re-OzSayin|Su Soğutmalı

Re-OzSayin W-600

600 kWR407CPistonlu3~ / 380–400 V / 50 Hz
Adana
Request PricingView
Trane RTHB300 — Su SoğutmalıRemanufacturedIn Stock
Trane|Su Soğutmalı

Trane RTHB300

1000 kWR22Vidalı3~ / 380–400 V / 50 Hz
Adana
Request PricingView
FAQ

Frequently Asked Questions

An industrial chiller is a closed-loop cooling machine that cools water or a water-glycol mixture through the evaporation-condensation cycle of a refrigerant. The chilled fluid is pumped to process equipment or air-handling coils, picks up heat, and returns to the chiller. The compressor, condenser, expansion valve and evaporator are its four core components.

What Is an Industrial Chiller?

An industrial chiller is a closed-loop mechanical cooling system that meets the cooling load required in manufacturing processes or large-scale air conditioning. It works on the principle that the refrigerant absorbs heat from water as it evaporates in the evaporator, is compressed in the compressor, and rejects heat to the surroundings as it condenses in the condenser. The chilled water is carried to the point of use by a pump loop.

Selecting the right chiller is not limited to capacity (kW) alone; the compressor type, refrigerant, condensing method (air/water), part-load efficiency (ESEER) and ambient conditions must all be evaluated together. A poorly chosen unit means both a high energy bill and frequent breakdowns.

Advantages of Air Cooled Chillers

Because air cooled chillers reject condensing heat directly to the air, they require no cooling tower, condenser-water pump or water-treatment infrastructure. This lowers both the initial investment and operating complexity. They are preferred in water-constrained regions and in projects that demand fast installation.

Modern air cooled units run far quieter and more efficiently than a few years ago, thanks to EC fans, inverter-driven scroll/screw compressors and microchannel condenser technologies. When equipped with a free cooling coil, their operating cost in cold climates approaches that of water cooled systems.

Applications of Water Cooled Chillers

Because water cooled chillers can operate at a low condensing temperature through the cooling tower, they are the most efficient solution at high capacities. They are common in data centers, pharmaceutical and food plants, plastic injection and metalworking factories that run continuously under high load.

Water cooled units with centrifugal compressors (including oil-free magnetic-bearing Turbocor) provide both high efficiency and low vibration at capacities above 1,000 kW. Proper design of the tower, pump and water treatment is critical to the system’s service life and efficiency.

What to Consider When Choosing a Chiller

During selection, the real process load and diversity factor should be determined first, then the target water temperature and ambient design temperature should be clarified. Choosing a low-GWP refrigerant (R513A, R1234ze) secures both compliance with F-Gas regulations and long-term refrigerant availability.

Part-load efficiency (ESEER) reflects the range where the unit will operate for most of the year; it is just as important as nominal COP. In addition, spare-parts availability, the service network and lead time directly affect the total cost of ownership. Özsayın offers a brand-independent, impartial selection that takes all of these criteria into account.