26 October 2026 · Özsayın

Headline or Data? The Picture Behind the 60% Refrigerant Price Hike Story

Headline or Data? The Picture Behind the 60% Refrigerant Price Hike Story

In May 2026, a news item in the trade press quickly pushed refrigerant onto the agenda of cooling operators' budget meetings: Beijer Ref UK, the UK's largest refrigeration and air-conditioning wholesaler, announced price increases of 60% for R410A and R407C, 35% for R134a and 30% for R32, effective 20 May. The reasons given were that the F-Gas regulation was "really starting to bite", market volatility and supply constraints.

In September of the same year, the European Commission published its quarterly price report. Based on data from 54 companies in 11 EU member states (3 gas producers, 14 distributors, 24 OEMs and 10 service providers), the report showed the following for the second quarter of 2026: R410A was up 2% on the previous quarter and 1% on the same quarter of the previous year.

Same refrigerant. Same year. One says 60%, the other 2%. This article looks at where that gap comes from and which figure a business should base its decisions on.

Both figures are correct, but they do not measure the same thing

The contradiction is only apparent. What is being measured is different:

  • The wholesaler announcement is a change in the list price of a single channel in a single country. Stock position, supply contracts and that channel's margin policy determine the price. When a wholesaler that has used up its cheap stock prices the next batch at the current quota cost, the jump shows up all at once.
  • The Commission data is an average indicator collected from eleven countries and four different types of market participant. An average smooths out channel-level jumps.

The practical conclusion: the percentage in the headline is not your own supplier's percentage, and the percentage in the average is not the price you will pay. Both indicate direction; neither is a budget line.

The line in the Commission data that matters most

The other lines in the same report show a trend that is easy to miss when focusing on a single refrigerant:

RefrigerantChange on previous quarterNote
R134a+1%Also +1% year on year
R410A+2%+1% year on year
R32+9%High increase among the alternatives
R290 (propane)+11%Highest increase in the report
R404A (reclaimed)−9%−9% for service companies, −4% for distributors

This table says the opposite of the common expectation that "high-GWP refrigerants are getting more expensive and low-GWP ones cheaper". The two refrigerants that became more expensive fastest in that quarter were R32 and R290, the very ones presented as transition targets. Reclaimed R404A, on the other hand, got cheaper.

The logic is simple: demand shifts to where regulation steers it, and price forms where demand goes. So the assumption that "my refrigerant cost will fall if I move to low GWP" is not reliable, at least in the short term.

The mechanism behind the price: quotas

In the EU, HFC supply is determined by quotas rather than by a free market. Importers and producers hold an allowance defined in CO2-equivalent terms, and this allowance can be bought from third parties. According to the same Commission report, in the second quarter of 2026 quota allowance prices ranged between €14 and €18.50 per tonne of CO2e, averaging €17.19, and were down 2% on the previous quarter.

What this figure means for a business: a significant part of the cost of a high-GWP refrigerant is not the gas itself but the CO2-equivalent burden it carries. The GWP of R410A is approximately 2,088; in other words, one kilogram of R410A represents more than two tonnes of CO2 equivalent in quota accounting. Every movement in the allowance price is reflected many times more strongly in high-GWP refrigerants than in low-GWP ones.

The case that shows how seriously quotas are taken

A case in the Netherlands shows that the quota is not just on paper. The Netherlands' Human Environment and Transport Inspectorate (ILT) imposed a conditional administrative fine of €66.76 per tonne of CO2e exceeded, capped at a maximum of €19.7 million, on Chemours' Dordrecht plant. The fine covers the 2026–2028 period and relates to imports of HFC23, which has a GWP of 14,800. The same authority had also issued a €1 million fine in 2023. In addition, the 964,724 tonne CO2e quota reduction applied by the European Commission for 2026 was taken by the company to the Court of Justice of the European Union; the court rejected the request for interim measures and the case is ongoing.

This is not price news but structural news: the quota is enforced, breaches are expensive, and the reductions are binding enough to be litigated. It is the most concrete evidence that the supply squeeze is not a temporary fluctuation.

What does it mean for a business in Türkiye?

Türkiye is not part of the EU quota system, but it is not outside the pool in which prices form either. We are affected through three channels:

  1. Import price: The supply squeeze in Europe pushes up the cost floor of refrigerant coming into Türkiye.
  2. Equipment side: For companies manufacturing for the EU market or buying equipment from the EU, the choice of refrigerant is now a commercial constraint. A high-GWP charge shortens the equipment's market life.
  3. Local regulation: Türkiye's own fluorinated greenhouse gas regulation is in force, and its registration, leak checking and certification obligations bind businesses directly.

Before stockpiling in a panic: a four-question decision framework

The first reflex on price-hike news is to stockpile. In most cases this is the wrong reflex: refrigerant stock ties up cash, brings storage and regulatory burdens, and is wasted investment if the equipment is going to be replaced anyway. Make the decision with these four questions:

1. What is your leak rate?

If your annual top-up quantity amounts to a significant share of the system charge, your problem is not price but tightness. The cheapest way to reduce refrigerant purchases is to stop the leaks; this is also a regulatory obligation. Look here before stockpiling.

2. How many years of life does the equipment have left?

If you expect more than five years of life, a refrigerant conversion or equipment renewal scenario is healthier than stockpiling refrigerant. If less than three years remain, a conversion will not pay back; a limited safety stock for service continuity and a cost-benefit analysis of the renewal decision should be considered together.

3. Is reclaimed refrigerant in the loop?

The most striking line in the Commission data was the price fall of reclaimed R404A. Recovery and reuse is the only channel that stays outside quota pressure. Collecting refrigerant from decommissioned systems is now a direct cost item, beyond being an environmental practice.

4. Which refrigerant are you moving to, and why?

The fact that R32 and R290 were the fastest-rising refrigerants in that quarter shows that the transition decision cannot be made on price alone. What is decisive is equipment compatibility, safety class (flammability precautions for A2L/A3), the certification of the service team and the regulatory horizon of the market. We covered these criteria in detail in our refrigerant comparison.

Frequently asked questions

Should I stockpile R410A now?

Only a limited quantity, and only if the remaining life of the equipment is short and there is a risk to service continuity. For a long-life plant, stock does nothing but postpone the conversion decision; quota pressure is moving in an increasing direction over time.

Will my refrigerant cost fall if I move to low GWP?

Not guaranteed in the short term. In the second quarter of 2026, R32 rose 9% and R290 rose 11%; in the same period R410A stayed at 2%. The advantage of low GWP shows up not in unit price but in protection from quota risk and future bans.

Is there a quota system in Türkiye?

Türkiye's own regulation on fluorinated greenhouse gases is in force and brings obligations for registration, reporting, leak checking and personnel certification. Because the scope of the obligations varies with the CO2-equivalent size of the system, each facility needs to be assessed on its own inventory.

Is reclaimed refrigerant safe?

Refrigerant that has been reclaimed in accordance with the standards and has undergone purity analysis is used in the same way as new refrigerant. What matters is that the process is documented and accompanied by an analysis report; undocumented refrigerant is a risk for both the equipment and regulatory compliance.

Conclusion

There is no single correct figure for refrigerant prices; there is a range that varies with channel, country and stock position. The gap between the 60% in the headline and the 2% in the average is not a contradiction but a sign of the fragmented structure of the market.

The right response for a business is not to argue about which figure is real but to do what is right regardless of price: close the leaks, bring recovery into play, and plan the conversion decision according to the remaining life of the equipment.

At Özsayın Soğutma, we provide technical support in refrigerant inventory, leak checking, refrigerant conversion and recovery processes. To map your facility's refrigerant risk together, get in touch with us.

Our services on this topic